Customization: | Available |
---|---|
Phase: | Single Phase |
Type: | Standby |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL | Giant 10K | Giant 15K | Giant 20K | Giant 30K | Giant 40K | Giant 60K | Giant 80K | Giant 100K | Giant 120K | Giant 160K | Giant 200K | |
CAPACITY | 10 KVA/ 8 KW |
15KVA/ 12KW |
20 KVA/ 16 KW |
30 KVA/ 24 KW |
40 KVA/ 32 KW |
60 KVA/ 48 KW |
80 KVA/ 64 KW |
100 KVA/ 80 KW |
120 KVA/ 96KW |
160 KVA/ 128KW |
200 KVA/ 160KW |
|
INPUT | ||||||||||||
Nominal Voltage | 3×380VAC/400VAC (3Ph+N) | |||||||||||
Acceptable Voltage Range | 285VAC~475VAC | |||||||||||
Frequency | 50/60 Hz±10% | |||||||||||
INVERTER | ||||||||||||
Nominal Voltage | 3×380VAC/400VAC (3Ph+N) | |||||||||||
Precision | Stationary:±1% Transitory:±5%(load variations 100-0-100%) |
|||||||||||
Frequency | 50/60 Hz synchronised±1% With mains absent±0.1 Hz |
|||||||||||
Max.Synchronization Speed | ±1 Hz/s | |||||||||||
Waveform | Pure Sinewave | |||||||||||
Total Harmonic Distortion (THDv) |
<2%(Linear Load);<5%(Non-linear Load) | |||||||||||
Phase Displacement | 120°±1%(balanced load);120°±2%(imbalances 50%of the load) | |||||||||||
Dynamic Recovery Time | 3 cycles at 90%of the static value | |||||||||||
Admissible Overload | 110%for 10min;150%for 60sec;>160%for 200ms | |||||||||||
Admissible Crest Factor | 3:1 | |||||||||||
Admissible Power Factor | 0.6~1 (inductive or capacitive) | |||||||||||
Imbalance Output Voltage @100%Unbalanced Load |
<1% | |||||||||||
Current Limit | High overload,short-circuit:RMS Voltage Limit High Crest-Factor current:Peak Voltage Limit |
|||||||||||
STATIC BYPASS | ||||||||||||
Type | Solid state | |||||||||||
Voltage | 3×380VAC/400VAC (3Ph+N) | |||||||||||
Frequency | 50/60 Hz | |||||||||||
Activation Criterion | Microprocessor control | |||||||||||
Transfer Time | Zero | |||||||||||
Admissible Overload | 150%for 1 hour;180%for 30sec;>200%for 200ms | |||||||||||
Transfer to Bypass | Immediate,for overloads above 160% | |||||||||||
Retransfer | Automatic after alarm clear | |||||||||||
MAINTENANCE BYPASS | ||||||||||||
Type | Without interruption | |||||||||||
Voltage | 3×400V (3Ph+N) | |||||||||||
Frequency | 50/60 Hz | |||||||||||
Overall Efficiency |
Line Mode | 89% | 90% | 91% | 92% | |||||||
Battery Mode | 90% | 91% | 92% | 93% | ||||||||
BATTERY&CHARGER | ||||||||||||
Battery Type and Numbers | 12VDC×32 pcs (29~32 pcs adjustable) | |||||||||||
Nominal Battery Voltage | 384 VDC(Based on 32pcs batteries) | |||||||||||
Charging Method | CC/CV | |||||||||||
Precision | ±1% | |||||||||||
Charging Current | Default 10A,*Maximum= Capacity(KW)/Battery (real-time). |
Default 10A;Maximum 40A;5A@full load | ||||||||||
Charging Voltage | 432 VDC (Based on 32pcs batteries) | |||||||||||
PHYSICAL | ||||||||||||
Dimensions,DxWxH(mm) | 656×405×817 | 656×405 x941 |
821x432x1159 | 975×554×1286 | 975×554x 1326 |
1051×705×1646 | ||||||
Net Weight(Kgs) | 118 | 120 | 145 | 193 | 278 | 365 | 471 | 573 | 650 | 760 | 840 |