Csb Gpl-121000 12V 100ah Sealed Lead Acid-AGM-VRLA Replacement Battery

Type: Lead-Acid Batteries
Usage: UPS, Electric Power, Lighting, Solar System
Nominal Voltage: 12V
Discharge Rate: High Discharge Rate
Shape: Square Battery
Electrolyte: Acid
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Rating: 5.0/5
Guangdong, China
to see all verified strength labels (11)

Basic Info.

Model NO.
GPL121000
Installation
Open Frame
Rechargeable
Chargeable
Capacity
100ah
Weight
Approx. 33.5kg. (73.83 Lbs.)
Maximum Discharge Current
800A (5 Sec.)
Internal Resistance
Approx. 3.2mΩ
Recommended Maximum Charging Current Lim
30A
Container Material
ABS
Transport Package
Carton
Specification
12v100ah
Trademark
CSB
Origin
Vietnam
HS Code
85072000

Product Description

GP stands for General Purpose. The series is a modern hi-tech energy application product, and the first generation delicate product in our company. Main features as follow:
When it is used in safe surroundings, the battery is maintenance free, adding water is unnecessary and it can be recharged repeatedly.
With isolated seal, it can be put in horizontal way, vertical way and side way, its safety and functions totally will not be affected.
With special formula to manufacture lead calcium alloy as well as automatic progresses, gassing will be less.
Long life, low self-discharge rate and high reliability.
It has safety, low resistance so recharge is easy and energy output is more remarkable.
Container material could be frame retardant ABS or PP with ranking UL 94V-0 by model.
Standby use.
High rate discharge construction.
Deep discharge recoverability.
Batteries are strictly tested by our patented computer charge/discharge system.
ISO9001, 14001, OHSMS 18001 certified.
UL recognized components under UL 1989 (file number MH14533).
Complies with IATA/ICAO Special Provision A67 for air transport.
Classified per MG Amendment 27 as a non-hazardous material for water transport.
Recognized by DOT as "Dry charge" 49 CFR 171-189 for surface transport.


Applications
Standby Use:
UPS power supplies
Workstation UPS
Emergency lighting equipment
Precision instrument backup power
Fire alarms and security systems
Communications and electric equipment
Office computers, processors and other office automation equipment
Robots, control equipment and other factory automation equipment
Emergency power supplies in power generation plants and substations
Telecommunications
Various telemeter equipment

Solar Cell Power Generation:
Street lighting
Portable power supply
Water pumping stations
Rural power systems

GPL121000
GPL121000
12 V 100.0Ah
GPL 121000 is a general purpose battery up to 10 years expected life under normal float charge.
As with all CSB batteries, all are rechargeable, highly efficient, leak proof and maintenance free
   
 
Specification  
Cells Per Unit 6
Voltage Per Unit 12 V
Capacity 100Ah @ 20hr-rate to 1.75 volts per cell @ 25°C (77°F)
Weight (kg) Approx. 33.5kg. (73.83 lbs.)
Maximum Discharge current (A) 800A (5 sec.)
Internal Resistance Approx. (mΩ) Approx. 3.2mΩ
Operating Temperature Range Discharge:-15ºC~50ºC(5°F~122°F)
Charge:-15ºC~40ºC(5°F~104°F)
Storage:-15ºC~40ºC(5°F~104°F)
Nominal Operating Temperature Range 25°C ± 3°C (77°F ± 3°F)
Float charging voltage 13.5 to 13.8 VDC/unit Average at 25°C (77°F)
Recommended Maximum Charging current limit 30A
Equalization and Cycle Service 14.4 to 15.0 VDC/unit Average at 25°C (77°F)
Self Discharge It should be more than 75% of the capacity that before storage after stocked for 6 months at ambient temp. 25ºC
Terminal I2-Thread lead alloy recessed terminal to accept M6 bolt
Container Material Polypropylene(UL 94-HB) & Flammability resistance of (UL 94-V0) can be available upon request.
     
 
Specification  
Cells Per Unit 6
Voltage Per Unit 12 V
Capacity 26 Ah @ 20hr-rate to 1.75V per cell @ 25°C (77°F)
Weight (kg) Approx. 8.45 kg. (18.62 lbs.)
Maximum Discharge current (A) 350 A (5sec.)
Internal Resistance Approx. Approx. 9.9 mΩ
Operating Temperature Range Discharge:-15ºC~50ºC(5°F~122°F)
Charge:-15ºC~40ºC(5°F~104°F)
Storage:-15ºC~40ºC(5°F~104°F)
Nominal Operating Temperature Range 25°C ± 3°C (77°F ± 5°F)
Float charging voltage 13.5 to 13.8 VDC/unit Average at 25°C (77°F)
Recommended Maximum Charging current limit 7.8 A
Equalization and Cycle Service 14.4 to 15.0 VDC/unit Average at 25°C (77°F)
Self Discharge It should be more than 75% of the capacity that before storage after stocked for 6 months at ambient temp. 25ºC
Terminal B1/B3/B3B-L terminal or Recessed type to accept M5 bolt
Container Material ABS(UL94-HB) & Flammability resistance of(UL94-V0) can be available upon request.

Csb Gpl-121000 12V 100ah Sealed Lead Acid-AGM-VRLA Replacement Battery

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company
Number of Employees
26
Year of Establishment
2013-04-02