Modular UPS Power 20kVA 25kVA 30kVA for Medical

Phase: Three Phase
Type: On-line
Protection: Overvoltage
Application: Communication
Classification: Lighting/Power
Standby Time: Long-acting Machine
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Rating: 5.0/5
Guangdong, China
to see all verified strength labels (11)

Basic Info.

Model NO.
modular ups
Standby UPS
Sine Wave Output UPS
Output Capacity
Medium Type
Equipment Mode
Decentralized
Brand
Kstar
Power Rating
25-1560 Kw
Output Power Factor
1
Voltage
380, 400, 415V
Frequency
50 or 60Hz
Efficiency
>96% in Double Conversion > 99% in Energy Saver Sy
Transport Package
Carton
Specification
200KVA
Trademark
kstar
Origin
China
HS Code
8504402000

Product Description

25-1560kVA
 
HPM series UPS is developed as a high frequency on line modular UPS for medium and large data center, adopting fully digital control technology, fully guarantee power supply to operate reliably and stably; diversified option of modular power, accurately position user side requirements; flexible redundancy design greatly increase the system availabity, user can realize expansion as demand, and modular structure greatly increase the convenience for maintenance.

General Features

Adopting digital control design, and the control system is more reliable

High power density design, capacity of single power module is 6KVA/ 10KVA/ 15KVA/ 20KVA/ 25KVA/ 30KVA/ 40KVA, the height of all these modules is 3U.The power of system ranged from 6KVA to 520KVA corresponds to the number of parallel power modules from 1 to 13

Redundant control system, each power module is equipped independent control system, and control itself independently according to the sharing message, and the fault module separates from the system automatically

Support parallel expansion for cabinet, and  parallel expansion is up to 4 cabinets.

Voltage of batteries can be configured flexibly, 1 input 1 output/ 3 input 1 output ±96Vdc/ ±108Vdc/ ±120Vdc(16/18/20PCS)selectable; 3 input 3 output±216Vdc/±228Vdc/±240Vdc (32/34/ 36/38/40PCS) selectable

Intelligent charging mode, Charging current can be configured , there are 3 charging mode  which are constant current mode,constant voltage mode,floating charging mode, and the charging mode can be transfer smoothly.

Technical Specification

MODEL HPM3325-250KVA HPM3330-90KVA HPM3330-150KVA HPM3330-300KVA HPM3340-200KVA HPM3340-320KVA HPM3340-400KVA HPM3340-520KVA HPM3340-800KVA HPM3340-1280KVA  HPM3340-1560KVA
Capacity (VA/Watts) UPS cabinet  250k / 225k 90k / 81k  150k / 135k 300k / 270k 200k/180k 320k/288k 400k / 360k 520k / 468k 800k / 720k 1280k / 1152k 1560k / 1404k
HPM module    25k / 22.5k  25k / 22.5k, 30k / 27k 40k / 36k
INPUT
Nominal voltage 380/400/415Vac, (3Ph+N+PE) 
Operating voltage range 208~478Vac for half load; 305~478Va c for full load 
Operating frequency range 40~70Hz
Power factor ≥0.99
Harmonic distortion (THDi) 3%(100% non-linear load)
Bypass voltage range 380Vac Max.voltage: +25%(optional +10%,+15%,+20% )
400Vac Max.voltage: +20% (optional +10%,+15%)
415Vac Max.voltage: +15% (optional +10%)
Min.voltage: -45% (optional -20%,-30%)
Bypass frequency range  Frequency synchronize tracing range:±10%
Generator access Support
OUTPUT
Rated voltage 380/400/415Vac(3Ph+N+PE)
Power factor 0.9
Voltage regulation ±1%
Frequency Line mode ±1%/±2%/±4%/±5%/±10% of the rated frequency(optional)
Bat. mode (50/60±0.1%)Hz
Crest factor 3:1
Harmonic distortion (THDv) ≤2% with linear load
≤5% with non-linear load  
Efficiency 95.00%
BATTERY
Battery voltage ±192/±204/±216/±228/±240Vdc; Battery quantity(optional)
Charging current(A) UPS cabinet  60A (Max.) 30A (Max.) 50A (Max.) 100A (Max.) 50A (Max.) 80A (Max.) 100A (Max.) 130A (Max.) 200A (Max.) 320A (Max.) 390A (Max.)
HPM module  6A (Max.)   25kVA:6A (Max.) / 30kVA:10A (Max.) 10A (Max.)
Backup time  Depends on the capacity of external batteries
SYSTEM FEATURES
Transfer time Utility to battery:0ms; Utility to bypass:0ms
Overload Line mode Load≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% turn to bypass mode immediately
Bat. mode Load≤110%: last 10min,≤125%: last 1min,≤150%: last 1S,≥150% shut down UPS immediately Load≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% shut down UPS immediately
Bypass mode  Breaker (25kVA:40A)  Breaker ( 25kVA:40A / 30kVA:60A)  40kVA:95A
Short circuit Hold whole system
Noise suppression Complies with EN62040-2
Communication interface UPS cabinet : RS232, RS485, Dry contact, Intelligent slot x 2(SNMP card,Relay card optional);
HPM series UPS module: RS232 
ENVIRONMENT
Operating temperature 0~40ºC
Storage temperature -25~55ºC
Humidity range 0~95% (Non-condensing)
Altitude <1500m. When >1500m, derating power for use
Noise level <70dB <65dB <70dB <73dB
PHYSICAL
Dimension D×W×H (mm) UPS cabinet  1100×600×2000  840×600×1400 1100×600×2000  850×600×1600 850×600×2000  850×1200×2000 850×2000×2000 850×3400×2000 4800×850×2000 
HPM module  443x580x131 (3U)
Net weight (kg) UPS cabinet  290 158 170 307 251 320 540 980 1400 2800
HPM module 32    25kVA/32; 30kVA/33.5 36
STANDARDS
Safety  IEC/EN62040-1,IEC/EN60950-1
EMC IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4, IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
Modular UPS Power 20kVA 25kVA 30kVA for MedicalModular UPS Power 20kVA 25kVA 30kVA for MedicalModular UPS Power 20kVA 25kVA 30kVA for MedicalModular UPS Power 20kVA 25kVA 30kVA for MedicalModular UPS Power 20kVA 25kVA 30kVA for MedicalModular UPS Power 20kVA 25kVA 30kVA for Medical

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company
Number of Employees
26
Year of Establishment
2013-04-02