Customizable Backup Tower Type UPS PF 1/0.9/0.8 with IEC Outlets Outputs From Chinese Factory 1kVA 2kVA 3kVA

Product Details
Customization: Available
Phase: Single Phase
Type: Standby
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Fast Delivery
The supplier can deliver the goods within 15 days
Low MOQ
The MOQ for the supplier's products is 1
OEM Services
The supplier provides OEM services for popular brands
R&D Capabilities
The supplier has 2 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (11)
  • Customizable Backup Tower Type UPS PF 1/0.9/0.8 with IEC Outlets Outputs From Chinese Factory 1kVA 2kVA 3kVA
  • Customizable Backup Tower Type UPS PF 1/0.9/0.8 with IEC Outlets Outputs From Chinese Factory 1kVA 2kVA 3kVA
  • Customizable Backup Tower Type UPS PF 1/0.9/0.8 with IEC Outlets Outputs From Chinese Factory 1kVA 2kVA 3kVA
  • Customizable Backup Tower Type UPS PF 1/0.9/0.8 with IEC Outlets Outputs From Chinese Factory 1kVA 2kVA 3kVA
  • Customizable Backup Tower Type UPS PF 1/0.9/0.8 with IEC Outlets Outputs From Chinese Factory 1kVA 2kVA 3kVA
  • Customizable Backup Tower Type UPS PF 1/0.9/0.8 with IEC Outlets Outputs From Chinese Factory 1kVA 2kVA 3kVA
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
Overview

Basic Info.

Model NO.
LY UPS 003
Protection
Overvoltage
Application
Fire Safety
Classification
Lighting/Power
Standby Time
Standard Machine
Standby UPS
Sine Wave Output UPS
Output Capacity
Medium Type
Equipment Mode
OEM
Brand
OEM
Customzied
Supported
OEM ODM
Supported
Sample Order
Supported
Factory
Supported
Transport Package
Carton
Specification
Carton
Trademark
OEM
Origin
China
HS Code
8506500000

Product Description

Product Description
 

•Compact size

•Excellent microprocessor control guarantees high reliability 

•Boost and buck AVR for voltage stabilization 

•Auto restart while AC is recovering 

•Simulated sine wave 

•Off-mode charging

•Cold start function 

•Generator compatible
 

Detailed Photos


Customizable Backup Tower Type UPS PF 1/0.9/0.8 with IEC Outlets Outputs From Chinese Factory 1kVA 2kVA 3kVA
Customizable Backup Tower Type UPS PF 1/0.9/0.8 with IEC Outlets Outputs From Chinese Factory 1kVA 2kVA 3kVACustomizable Backup Tower Type UPS PF 1/0.9/0.8 with IEC Outlets Outputs From Chinese Factory 1kVA 2kVA 3kVACustomizable Backup Tower Type UPS PF 1/0.9/0.8 with IEC Outlets Outputs From Chinese Factory 1kVA 2kVA 3kVACustomizable Backup Tower Type UPS PF 1/0.9/0.8 with IEC Outlets Outputs From Chinese Factory 1kVA 2kVA 3kVACustomizable Backup Tower Type UPS PF 1/0.9/0.8 with IEC Outlets Outputs From Chinese Factory 1kVA 2kVA 3kVACustomizable Backup Tower Type UPS PF 1/0.9/0.8 with IEC Outlets Outputs From Chinese Factory 1kVA 2kVA 3kVACustomizable Backup Tower Type UPS PF 1/0.9/0.8 with IEC Outlets Outputs From Chinese Factory 1kVA 2kVA 3kVACustomizable Backup Tower Type UPS PF 1/0.9/0.8 with IEC Outlets Outputs From Chinese Factory 1kVA 2kVA 3kVACustomizable Backup Tower Type UPS PF 1/0.9/0.8 with IEC Outlets Outputs From Chinese Factory 1kVA 2kVA 3kVACustomizable Backup Tower Type UPS PF 1/0.9/0.8 with IEC Outlets Outputs From Chinese Factory 1kVA 2kVA 3kVACustomizable Backup Tower Type UPS PF 1/0.9/0.8 with IEC Outlets Outputs From Chinese Factory 1kVA 2kVA 3kVACustomizable Backup Tower Type UPS PF 1/0.9/0.8 with IEC Outlets Outputs From Chinese Factory 1kVA 2kVA 3kVACustomizable Backup Tower Type UPS PF 1/0.9/0.8 with IEC Outlets Outputs From Chinese Factory 1kVA 2kVA 3kVA

Product Parameters
 

 

Model LY-UT11 1101S 1101  1102S 1102  1103S 1103 
Capacity/Power 1kVA/1kW 2kVA/2kW 3kVA/3kW
Input Input Configuration L+N+PE
Rated input voltage 208/220/230/240VAC
Voltage range 110~300VAC
Frequency range 44~56Hz or 54Hz~66Hz,Default
Input power factor ≥0.99
THDi ≤4%(Linear Load)
≤5%(Non-linear Load PF=0.8)
Output Output Configuration L+N+PE
Output voltage 208/220/230/240VAC
Output accuracy ±1%

Output frequency

Online Mode:Follow the mains frequency,Battery mode:50/60Hz±0.1%
THD ≤3%(Linear Load)
≤5%(Non-linear Load)
Output power factor
Switching time Mains mode→Battery mode:0ms,Inverter mode-Bypass mode:4ms
Overload capacity
Mains mode:30min@102%~110%Load;10min@110%~130%Load;30s@130%~150%Load;
                               200ms@>150%Load
Battery mode:1min@102%~110%Load;10s@110%~130%Load;3s@130%~150%Load;200ms@>150%
                                        Load
Efficiency(Mains Mode) 94.5% 95.5% 95.5 
Battery Battery voltage Built-in 2×12V
7AH/9AH battery
36Vdc Built-in 4×12V
7AH/9AH battery
72Vdc Built-in 6×12V
7AH/9AH battery
96Vdc
Charging current 1A 1-12A(max) 1A 1-12A(max) 1A 1-12A(max)
Display interface LCD display interface,support operation mode/load/power/input/output,etc.
communication interface RS232 as standard,optional SNMP smart card and USB interface
Environment Operating
temperature
0~40ºC
Operating Humidity 20%~95%non-condensing
Altitude Should not exceed 1000m,derate above 1000m,with a maximum of 4000m,refer to IEC 62040.

Dimensions
W×D×H(mm) 145×315×219 145×400×219 190×454×322 145×400×219

Weight
Net weight(kg) 8.6/9.6 15.4/17.4 6.2  21/24 6.4 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier