• Wholesale Pure Sine Wave Rack Mount Online UPS 30kVA
  • Wholesale Pure Sine Wave Rack Mount Online UPS 30kVA
  • Wholesale Pure Sine Wave Rack Mount Online UPS 30kVA
  • Wholesale Pure Sine Wave Rack Mount Online UPS 30kVA
  • Wholesale Pure Sine Wave Rack Mount Online UPS 30kVA
  • Wholesale Pure Sine Wave Rack Mount Online UPS 30kVA

Wholesale Pure Sine Wave Rack Mount Online UPS 30kVA

Phase: Single Phase
Type: On-line
Protection: Unbalanced Loads
Application: Communication
Classification: Lighting/Power
Standby Time: Standard Machine
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Rating: 5.0/5
Guangdong, China
to see all verified strength labels (11)

Basic Info.

Model NO.
rack 30k
Standby UPS
Sine Wave Output UPS
Output Capacity
Small Type
Equipment Mode
Centralized Model
Brand
OEM
Nominal Voltage
220/230/240VAC
Operating Voltage Range
110~300VAC
Power Factor
0.9
Crest Factor
3:1
Efficiency
95%
Transport Package
Carton
Specification
3000va
Trademark
oem
Origin
China
HS Code
8504402000

Product Description

YDC3300-RT (10-50kVA)
10-50kVA

single phase 3 phase online ups rackmount ups 10kva 15kva 20kva 
 
Building on the best-in-class reliability of the KSTAR UPS platform, the YDC3300-RT rack-mounted UPS provides a dependable and cost-effective power backup solution with a higher power density, a smaller footprint that makes it the ideal solution for distributed IT and edge computing environments.

General Features

Double conversion online design

Input power factor correction (PFC) technology

input power factor up to 0.99

Digital control process (DSP) makes the system more stable and reliable

Parallel redundance function, max six in parallel

LSB synchronization (40~50KVA).

Battery pack can be common connection in parallel operation

30~50 pcs battery are settable

Intelligent charging management

LED+LCD display

Self-diagnosis function

EPO function

Technical Specification

MODEL YDC3310-RT YDC3315-RT  YDC3320-RT YDC3330-RT   YDC3340-RT  YDC3350-RT
Capacity (VA/Watts) 10k/10k  15k/15k 20k/20k  30k/30k 40k/40k  50k/50k
INPUT 
 Input&Output System 3/3,3/1,1/1 , Support Double sources input   3/3, Support Double sources input
Nominal Voltage 380/400/415 (3Ph+N+PE) ; 220/230/240 (P-N) 380/400/415 (3Ph+N+PE) 
Operating voltage range 208~485   138~485
Operating frequency range 40~70Hz
Power Factor ≥0.99
Harmonic distortion (THDi) ≤3% (100% linear load)
 Bypass input 
 Normal voltage (Vac)  3/3,3/1,1/1 , Support Double sources input 3/3, Support Double sources input 
Bypass voltage range Max. voltage:220V: +25%(optional +10%,+15%,+20% ) ; 
230V: +20%(optional +10%,+15% ) ; 
240V: +15%(optional +10%) 
Min. voltage: -45% (optional -10%,-20%,-30%) 
Bypass Frequency range Frequency protection range: ±10% 
Generator input Support
OUTPUT  
Output Voltage 380/400/415Vac,(3Ph+N+PE) 
220/230/240Vac,(P-N)
380/400/415Vac (3Ph+N+PE) 
Power Factor 1.0
Output frequency(Hz) Line mode:Synchronize with input ;when input frequency >±10%%(±1%,±2%,±4%,±5% Optional,
Output frequency 50×(1±0.1%)Hz Battery mode :(50/60±0.1%)Hz 
Waveform Pure sine wave 
Crest factor 3:1 
Harmonic distortion(THDV) ≤2%(100% linear load); ≤4% (100% non linear load)  
Transfer Time(ms)  0 Ms
Efficiency UP to 95  UP to 96
Overload ≤110% overload for 60 min; 125% overload for 10 min; ≤150% overload for 1 min  
Bypass Mode 135% overload for long term; >1000% overload for 100 ms  135% overload for long term; >1000% overload for 100 ms 
BATTERY
Battery Voltage For optional : Optional Voltage: ±180/192/204/216/228/
240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/
46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 30 pcs default, 36~50 pcs fully output ; 32~34 pcs
Out put power factor 0.9; 30 pcs output power factor 0.8;)
For optional : Optional Voltage: ±180/192/204/216/228/240
/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/
50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs
default, 36~50 pcs fully output ; 32~34 pcs
Out put power factor 0.9; 30 pcs output power factor 0.8;) 
Max charger current (A)                            18                       20 18 20 
 Others    
 Alarm function     Overload,utility abnormal,UPS fail,battery low voltage etc
 Protection function  Short circuit,overload,overheat,battery low,output low voltage,fan fault,Anti-thunder
SYSTEM FEATURES
Overload Line Mode Load≤110%: last 60min, ≤125%: last 10min, ≤150%: last 1min, ≥150% turn to bypass mode immediately
Bat. Mode Load≤110%: last 10min, ≤125%: last 1min, ≤150%: last 5S, ≥150% shut down UPS immediately 
Bypass Mode Breaker( Load < 125%, long-term operation)
Short circuit  Hold whole system 
Communication interface RS232, RS485, Parallel, Intelligent Slot(SNMP card/ Relay card(optional)), 
BMS (optional),EPO port, Output port, MAINTAIN-AUXSWS
PHYSICAL 
Dimension W×H×D (mm) 443x131(3U)x580 mm  440x670x130(3U) 440x800x175( 4U) 
Net Weight (kg) 29 31 32   27  48  51 
ENVIRONMENT
Operating temperature 0~40ºC
Storage  temperature -25ºC~60ºC 
Humidity range 0~95% (non-condensing)
Altitude <1500m(when excess 1500m, according to GB/T 3859.2 to derating)
Noise Level <55db  <58   <62 <65 
STANDARDS
Safety  IEC/EN62040-1,IEC/EN60950-1 
EMC  IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
Wholesale Pure Sine Wave Rack Mount Online UPS 30kVAWholesale Pure Sine Wave Rack Mount Online UPS 30kVAWholesale Pure Sine Wave Rack Mount Online UPS 30kVAWholesale Pure Sine Wave Rack Mount Online UPS 30kVAWholesale Pure Sine Wave Rack Mount Online UPS 30kVAWholesale Pure Sine Wave Rack Mount Online UPS 30kVA

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company
Number of Employees
26
Year of Establishment
2013-04-02